Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Scope Of Supply; Technical Specifications; Installing The Appliance - Siemens KI82L Serie Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für KI82L Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en Installation and connection
5
Installation and
connection
S cope of supply
I n s t a l l a t i o n a n d c o n n e c t i o n
After unpacking all parts, check for any
damage in transit.
If you have any complaints, contact the
dealer from whom you purchased the
appliance or our customer service.
~ "Customer service" on page 37
The delivery consists of the following
parts:
Built-in appliance
Interior fittings (depending on model)
Installation material
User manual
Installation instructions
Customer service booklet
Warranty enclosure
Information on the energy
consumption and noises

Technical specifications

Refrigerant, cubic capacity and further
technical specifications can be found on
the rating plate.
~ "Getting to know your appliance"
on page 27

Installing the appliance

Installation location
The more refrigerant an appliance
contains, the larger the room must be in
which the appliance is situated. In
rooms which are too small leaking
refrigerant can form a flammable gas-air
mixture.
Per 8 g of refrigerant the room must be
at least 1 m³ in size. The amount of
refrigerant in your appliance is indicated
on the rating plate inside the appliance.
~ "Getting to know your appliance"
on page 27
24
The weight of the appliance may be up
to 73 kg depending on the model.
Permitted room temperature
The permitted room temperature
depends on the climatic class of the
appliance.
Information on the climatic class can be
found on the rating plate.
~ "Getting to know your appliance"
on page 27
Climatic cate-
Permitted room temperature
gory
SN
+10 °C ... 32 °C
+16 °C ... 32 °C
N
ST
+16 °C ... 38 °C
T
+16 °C ... 43 °C
The appliance is fully functional within
the permitted room temperature.
If an appliance of climatic class SN is
operated at colder room temperatures,
the appliance will not be damaged up to
a room temperature of +5 °C.

Cavity dimensions

Cavity depth
A cavity depth of 56 cm is
recommended for the appliance. If the
cavity depth is smaller – at least 55 cm
– the energy consumption increases
slightly.
Cavity width
An inside cavity width of at least 56 cm
is required for the appliance. If this is
not the case, problems may occur when
installing the appliance.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ki72l serieKi82lad40

Inhaltsverzeichnis