Page EN-30
Troubleshooting table
Problem
Possible cause
T h e
a p p l i a n c e
Ambient temperature too
doesn't cool suffi-
low or too high.
ciently.
Compressor seems defec-
tive.
The display shows
A component for regulat-
the following:
ing the humidity in the unit
has been inadvertently
switched off.
Appliance is mak-
Operating noises are func-
ing a noise.
tional and are not a sign of
malfunction.
Disturbing noises.

Error messages

If one of the following error messages appears on the display, please contact our service depart-
ment (see page EN-31):
Error code
Error description
E1
Temperature sensor error in fridge
E2
Temperature sensor error in freezer
E4
Defrost sensor error in fridge compartment
E5
Defrost sensor error in freezer
E6
Communication error
E7
Error on the sensors for the monitoring of the temperature circulation
EH
Moisture sensor error
Solutions, tips, explanations
Adjust ambient temperature (see "Intended
use" on page EN-4).
Activate "SUPER FRZ." and "SUPER COOL"
simultaneously (see "MODE" on page EN-13).
If the compressor does not switch on within an
hour, please contact our service department
(see page EN-31).
Please switch it on again to ensure proper op-
eration of your appliance:
• Press and hold the sensor button FRZ.
TEMP. (15). Hold for 7 seconds until the
display shows "ON" for 3 seconds and
there is an audible beep.
Humming: Refrigeration unit is running.
Flowing noise: Refrigerant is flowing through
the pipes.
Clicking: Compressor is switching on or off.
Check that it is stable.
Remove any objects from the appliance.
Remove any foreign matter from the back of
the appliance.