Herunterladen Inhalt Inhalt Diese Seite drucken

Chapter 4 - Programming; Easy Programming Mode; Advanced Programming Mode - Desoutter EAP-Tflex Bedienerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63
Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
10 /
There are 2 ways to program the tool: the Easy Programming mode and the Advanced Programming mode. The Easy
Programming mode allows to change the torque. In the Advanced Programming mode, all parameters can be changed: the torque
preset, the result recording selector, the joint stiffness, the access code and the unit. The Advanced Programming mode also
allows for a calibration.

1 - EASY PROGRAMMING MODE

The torque can be changed in the Easy Programming mode.
Action
Press
during 3s to enter the Easy Programming
mode.
Press
or
to change the torque (torque
resolution = 0.1 Nm).
Press
during 3 s to validate the target torque.
By default, if no key is pressed during 60 s, the tool switches back into tightening mode without saving the parameters.

2 - ADVANCED PROGRAMMING MODE

The Advanced Programming mode can be used to change the preset torques, to record the data, to change the joint stiffness, to
activate an access code, to change the unit and to calibrate the tool. It allows for escaping without any change.
Action
Press
and
simultaneously during 3 s, starting
with
, to enter the Advanced Programming mode.
Press
to reach the next menu item.
Press
to reach the next menu item.
Press
to reach the next menu item.
Press
to reach the next menu item.
EAP-TFlex tools

CHAPTER 4 - PROGRAMMING

Display / Result
Easy Programming mode: the torque value "XX.X" flashes.
The "Torque" LED lights ON.
The torque is increased or decreased, according to the
pressed buttons. Eventually, the target torque is reached.
The target torque is validated. "--" is displayed. The
"Torque" LED lights OFF.
Ready to tighten.
Display / Result
Advanced Programming mode
1st menu item - Torque Preset (max. 6 torques can be preset)
"Toff" is displayed by default: the Torque Preset mode is
not selected. The "Torque" LED lights ON.
2nd menu item - Data Recording
"Roff" is displayed by default: the torque data will not be
recorded. The "REC" LED lights ON.
3rd menu item - Joint Stiffness
"MED" is displayed by default: medium stiffness is
selected. Other possible values for the joint stiffness are
"HARD" and "SOFT".
4th menu item - Access Code Activation
"---0" is displayed by default: it means that no Access Code
is activated. The "Access Code" LED lights ON.
5th menu item - Unit Selection

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eap2-65-tfEap2-30-tf

Inhaltsverzeichnis