  • DEUTSCH, seite 117
The cable with integrated temperature sensor has to be purchased
separately (part no: ASS000100000). This temperature sensor is not
interchangeable with other Victron temperature sensors, as used with
Multis/Quattros or battery chargers.
1.3 Important combined button functions
(see also section 4.1: using the menus)
a) Restore factory settings
Press and hold SETUP and SELECT simultaneously for 3 seconds
b) Manual synchronization.
Press and hold the up and down buttons simultaneously for 3 seconds
c) Silence audible alarm
An alarm is acknowledged when any button is pressed. However, the
alarm icon is displayed as long as the alarm condition remains.
1.4 Real-time data displayed on a smartphone
With the VE.Direct Bluetooth Smart dongle real time data and alarms can
be displayed on Apple and Android smartphones, tablets and other
devices