Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt
The HAMEG Instruments GmbH herewith declares conformity of the product
HAMEG Instruments GmbH déclare la conformite du produit
Bezeichnung / Product name / Designation:
Typ / Type / Type:
mit / with / avec:
Optionen / Options / Options:
mit den folgenden Bestimmungen / with applicable regulations / avec les
directives suivantes
EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG
EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE
Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE
Angewendete harmonisierte Normen / Harmonized standards applied /
Normes harmonisées utilisées
Sicherheit / Safety / Sécurité
EN 61010-1:2001 (IEC 61010-1:2001)

General information regarding the CE marking

HAMEG instruments fulfill the regulations of the EMC directive. The conformity
test made by HAMEG is based on the actual generic- and product standards. In
cases where different limit values are applicable, HAMEG applies the severer
standard. For emission the limits for residential, commercial and light industry
are applied. Regarding the immunity (susceptibility) the limits for industrial
environment have been used.
The measuring- and data lines of the instrument have much influence on
emmission and immunity and therefore on meeting the acceptance limits. For
different applications the lines and/or cables used may be different. For
measurement operation the following hints and conditions regarding emission
and immunity should be observed:
1. Data cables
For the connection between instruments resp. their interfaces and external
devices, (computer, printer etc.) sufficiently screened cables must be used.
Without a special instruction in the manual for a reduced cable length, the
maximum cable length of a dataline must be less than 3 meters and not be
used outside buildings. If an interface has several connectors only one
connector must have a connection to a cable.
Basically interconnections must have a double screening. For IEEE-bus
purposes the double screened cables HZ72S and HZ72L from HAMEG are
suitable.
2. Signal cables
Basically test leads for signal interconnection between test point and
instrument should be as short as possible. Without instruction in the manual
for a shorter length, signal lines must be less than 3 meters and not be used
outside buildings.
Signal lines must screened (coaxial cable - RG58/U). A proper ground
connection is required. In combination with signal generators double screened
cables (RG223/U, RG214/U) must be used.
3. Influence on measuring instruments.
14
Subject to change without notice
HAMEG Instruments GmbH
KONFORMITÄTSERKLÄRUNG
Industriestraße 6

DECLARATION OF CONFORMITY

D-63533 Mainhausen
DECLARATION DE CONFORMITE
Funktions-Generator
Function Generator
Generateur de fonction
HM8130
Überspannungskategorie / Overvoltage category / Catégorie de surtension: II
Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2
Elektromagnetische Verträglichkeit / Electromagnetic compatibility /
Compatibilité électromagnétique
EN 61326-1/A1 Störaussendung / Radiation / Emission:
Tabelle / table / tableau 4; Klasse / Class / Classe B.
Störfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1.
EN 61000-3-2/A14 Oberschwingungsströme / Harmonic current emissions /
Émissions de courant harmonique:
Klasse / Class / Classe D.
EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fluctuations and
flicker / Fluctuations de tension et du flicker.
Datum /Date /Date
01.12.2004
Under the presence of strong high frequency electric or magnetic fields, even
with careful setup of the measuring equipment an influence of such signals is
unavoidable.
This will not cause damage or put the instrument out of operation. Small
deviations of the measuring value (reading) exceeding the instruments
specifications may result from such conditions in individual cases.
HAMEG GmbH
Unterschrift / Signature /Signatur
G. Hübenett
Produktmanager