Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until
the end of the guarantee period.
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
Cordless submersible pressure/rainwater bar-
rel pump with battery box
Fastening hook
Set of tubes
Original operating instructions

3. Proper use

The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially not for engine fuels,
cleaning agents and other chemically-based
products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment's anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Anl_GE_PP_18_RB_Li_SPK9.indb 19
Anl_GE_PP_18_RB_Li_SPK9.indb 19
GB
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.

4. Technical data

Voltage ....................................................18 V d.c.
Max. pumping rate .................................3,000 l/h
Delivery head maximum ............................. 20 m
Max. delivery pressure....................... 0.20 MPa
(2.0 bar)
Max. immersion depth ................................... 4 m
Water temperature maximum ...................... 35°C
Hose connection ........approx. 33.3 mm (1") male
thread
Max. size of foreign bodies: .............. Clean water
Suction height .......................min. approx. 15 mm
Minimum water level when starting up ..... 50 mm
Type of protection of pump: ..........................IPX8
Type of protection of battery box: .................IPX4
Using the pump with the set of tubes
Max. pumping rate .................................1,800 l/h
Delivery head maximum ............................. 20 m
Max. delivery pressure ...........0.20 MPa (2.0 bar)
Important!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power X-
Change series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with the
Power X charger.

5. Before starting the equipment

The equipment is supplied without batteries
and without a charger.
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.