BTL7-A/C/E/G5 _ _ -M _ _ _ _ -HB/WB-KA_ _/K_ _/FA_ _/F_ _
Micropulse Transducer - Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a linear encoder. It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original BALLUFF accessories.
Use of any other components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.
BTL7...HB/WB-...
Axial
Mounting surface
55
0.5 / Ø 25
29.5
4)
Ø 5 for hook spanner
Ø 58–62
BTL7...HB/WB-...
Radial
M18x1.5
24
1
english
HB: 30-1 mm
WB: 2"-0.04"
Nominal length =
60
2)
Measuring range
3)
Magnet
Thread size:
HB: M18×1.5
25
WB: 3/4"-16UNF
45

Downloading further instructions

A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
Dimensions and function
The Micropulse Transducer contains the waveguide which
is protected by an outer stainless steel tube (rod). A
magnet is moved along the waveguide. This magnet is
connected to the system part whose position is to be
determined.
Installation
NOTICE
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
► The mounting surface of the transducer must make
full contact with the supporting surface.
► The bore must be perfectly sealed (O-ring/flat seal).
1) Not for BTL7-...-FA_ _ and BTL7-...-F_ _
2)
Damping zone
60
Thread
M4x4/6 deep
2) Unusable area
3) Not included in scope of delivery
4) Connecting option for cable protection system
with M18
File no. 1)
E227256
Ø 60
45