BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system and used in the industrial sector. Flawless function
in accordance with the specifications in the technical data
is ensured only when using original BALLUFF accessories.
Use of any other components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete user's guide and the configuration guide can
be downloaded from the Internet at www.balluff.com or
requested via e-mail from service@balluff.de.
Output signal rising
100% +10 mm
100%
0%
-10 mm
Error signal
Warning
signal
1)
13
63
~80
1) Unusable area
2) Not included in scope of delivery
1
english
Null point
1)
Nominal length =
10
Measuring range
2)
~250
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder head screws,
max. tightening torque 2 Nm

Electrical connection

Pin assignment of S115 connector (view
from above on transducer)
PIN
Color
1
2
OG/WH Orange/
white
3
OG
Orange
4
5
GN/WH Green/white
6
BU
Blue
7
BN
Brown
8
GN
Green
1) Unassigned leads that are not used can be connected to the GND on
the controller side but not to the shield.
2) Reference potential for supply voltage and EMC-GND.
Dimensions and function
The transducer contains the waveguide. A magnet is
moved along the waveguide. This magnet is connected to
the system part whose position is to be determined.
LED
Operating state
Green
Ethernet Connection available
Orange
Data is being transmitted via the VARAN bus.
End point
Error signal
Warning
signal
1)
1)
10
63
~250
~80
File No.
E227256
BTL6-V5 _ V-... interface
Not used 1)
TX+
TX−
Not used 1)
RX+
GND 2)
10...30 V
RX−
BTL5-P-3800-2 magnet
2)
LED
34.8
50
68