8.2 Materials

8.2.1 Material for PE-LD and FEP
Use a 6-core, shielded cable with integrated pressure compensation hose
and AWG 24 with ferrules.
Type
Outer sheath
Pressure
compensation hose
Outer diameter
Conductor
cross-section
Bending radius:
Tensile strength
Weight
Medium temperatures
UV resistance
20
Description
PE-LD, black cable.
FEP, black cable. Depending on the version
ordered.
PA
Approx. 8.4 mm.
2
0.25 mm
.
Moving: 160 mm.
Fixed: 120 mm.
It is important to take into account that if the
protective hose is pinched, it prevents ambient
pressure compensation.
Up to 400 N.
PE-LD cable: approx. 115 g/m.
FEP cable: approx. 90 g/m.
-20 to +60 °C.
PE-LD according to VDE 0207.
FEP cable according to DIN ISO 4892-2.