8

Troubleshooting

If a fault cannot be resolved by means of the ac-
tions described here, please refer to Weidmüller
Service.

8.1 Fault table

Fault
Machine cannot be switched
on.
Cannot start with inserted
wire.
Increased scrap

8.2 Error messages

Fault

8.3 Wear parts

Product
Titanium stripping blades
Stripping blades V-radius 2.09
Stripping blades V-radius 6.20
32
Possible cause
No power supply
Start sensor (S1) is blocked by strip-
ping leftovers.
Wire has been inserted incorrectly.
Waste container is full
Stripping blades damaged or incorrect-
ly installed
Control knob cross section adjusted
Possible cause
Drawer is open
(only on the Power Stripper 16)
Stop switch fault
– Stop switch does not switch off
– Stop switch is still pressed
Stop switch fault
– Start switch not free
Motor fault
– Motor not running or motor jammed
Servicing message
– Piece quantity for servicing reached
Order no.
9050180000
1120920000
1120910000
Recommended action
► Check the power cable and the mains connec-
tions.
► Check fuses.
► Go to inching
mode.
► Remove the leftovers from the stripping unit.
► Insert the wire straight.
► Empty the waste container (see section 7.4).
► Check the seating of the stripping blades (see
section 7.7).
► Adjust or replace the blades (see section 8.4).
► Check the setting.
Recommended action
► Close the drawer
► Press touch display briefly
► Press touch display briefly
► Press touch display briefly
► Send machine in for servicing
2562260000/01/10.2017