• Keep to the specified cable cross section and fit a cable fuse (fig. 8 3, page 5)
as close to the battery as possible on the positive cable (see the table).
Device
MSI912
MSI924
MSI1312
MSI1324
MSI1812/MSI1812T
MSI1824/MSI1824T
9.2
Connecting the inverter to the battery
I
NOTE
Tighten the nuts and bolts to a maximum torque of 12 – 13 Nm. Loose
connections may cause overheating.
➤ Set the main switch (fig. 6 1, page 4 and fig. 7 1, page 5) to "OFF".
➤ Loosen the screw (fig. 8 1, page 5) from the red positive terminal (fig. 8 2,
page 5).
➤ Push the cable lug (fig. 8 2, page 5) of the positive cable into the red positive
terminal and fasten it with the screw.
➤ Connect the negative cable to the black negative terminal (fig. 8 4, page 5).
➤ Lay the positive cable from the inverter to the positive terminal of the vehicle
battery and connect it.
➤ Lay the negative cable from the inverter to the negative terminal of the vehicle
battery and connect it.
➤ Connect the earth terminal to the vehicle chassis.
EN
Required cable
cross section
25 mm²
25 mm²
35 mm²
35 mm²
35 mm²
35 mm²
Connecting the inverter
Cable fuse
(fig. 8 3, page 5)
115 A
75 A
170 A
85 A
228 A
115 A