Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SIMATIC Ident Funktionshandbuch Seite 56

Vorschau ausblenden Andere Handbücher für SIMATIC Ident:
Inhaltsverzeichnis

Werbung

Parametrieren der Anweisungen
4.5 Anweisungen programmieren
Tabelle 4- 36 ATTRIBUTE "0x6F" (Datentyp "IID_READSTAT_EF_RF300G2")
Name
status info
hardware
hardware_version
reserved
loader
loader version 1
loader version 2
loader version 3
loader_version_4
firmware
firmware version 1
firmware_version_2
firmware version 3
firmware_version_4
reserved1
driver
driver version 1
driver version 2
reserved2
Tabelle 4- 37 ATTRIBUTE "0xA2" (Datentyp "IID_CM_STATUS_A2") kompatibel mit RF18xC/RF18xCI
Name
status info
hardware_version
firmware_version
config ID
serial_number
device_type
upload request
active_connections
io_mode
low_voltage
reserved0
reserved1
number serial interfaces
serial_interface_data
connection_status
56
Typ
Kommentar
SINT
Reader status mode
SINT
Type of hardware
INT
Version of hardware
0 = RF310R, RF340R, RF350R; 1 = RF380R, RF260R; 2
= RF310R (ISO), RF210R, RF220R; 3 = RF380R (ISO),
RF240R; 4 = RF340R (ISO), RF350R (ISO), RF250R; 5
= RF310R (ISO); A = RF310R Gen2, RF290R; B =
RF340R Gen2; C = RF350R Gen2; M = RF280R RS422; N
= RF280R RS232
INT
Reserved
SINT
Type of loader
SINT
Version of loader
SINT
Version of loader
SINT
Version of loader
SINT
Version of loader
SINT
Type of firmware
SINT
Version of firmware
SINT
Version of firmware
SINT
Version of firmware
SINT
Version of firmware
DINT
Reserved
SINT
Type of driver
SINT
Version of driver
SINT
Version of driver
INT
Reserved
Typ
Kommentar
SINT
CM device status
SINT
Version of hardware
SINT[4]
Version of firmware
DINT
Config ID as unix timestamp
SINT[16]
Serial number
SINT
Type of device
0x00 = RF185C; 0x01 = RF186C; 0x02 = RF188C; 0x03
= RF186CI; 0x04 = RF188CI
SINT
Upload request for configuration data
SINT
Active connections
0x00 = PLC; 0x01 = OPC UA; 0x02 = XML
SINT
Mode of in-/outputs
0x00 = Disabled; 0x01 = Single Input; 0x02 = Sin-
gle Output; 0x03 = Support of IO link devic-
es/hubs
SINT
Low voltage warning
0x00 = OK; 0x01 = low voltage
SINT
Reserved
SINT
Reserved
SINT
Number of serial interfaces supported by CM
IID IN
SERIAL
INTERFACE[4]
SINT
Status of communication between reader and CM
0x00 = down; 0x01 = up
Ident-Profil, Add-On Instruction für Rockwell-Systeme
Funktionshandbuch, 07/2020, C79000-G8900-C410-04

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis