INSTALLATION INSTRUCTIONS
The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
• The cut out sizes are:
Model
PI3100
PI3400
> 20mm
Optimized
ventilation
• The plate is equipped with two fans located at the bottom. Please observe the distances
for the circulation of the ventilation air.
•
Ensure that there is a distance of 50mm
•
The ventilation distance between the plate base and the upper section of a ventilated oven
or drawer, must beat least 20mm. The separation distance for non forced ventilation ovens
must be greater in accordance with the oven manufacturer's recommendations.
Stick the gasket (2) two millimeters from
the external edge of the glass, after
removing the protection sheet (3).
Cut size
Width
Depth
560
490
780
340
between the hob and the wall or sides.
19
Glass size
Width
Depth
590
520
810
370
¡ATTENTION!
Inproper installation
and dailure to
observe the
ventilations may lead
to malfunction of
breakdown of the
device that is not
covered by the
manufacturer's
warranty
Thickness
4
4