Medema Mini Crosser M2 Wartungsanleitung Seite 65

Inhaltsverzeichnis

Werbung

Medema Production A/S
Code Description
1C10
Motor negative current trip
1C12
Reverse overcurrent trip
1E08
Inhibit active
1E09
Inhibit active
1E0A
Inhibit active
2100
Programming corrupted
2A12
Forward overvoltage trip
2A10
Motor positive voltage trip
2B10
Motor negative voltage trip
2B12
Reverse overvoltage trip
2C00
Battery Voltage Trip
2E00
Main loop ran out of time
2F01
Throttle displacement trip
3100
Voltage on Bridge too low trip
3201
Internal Processor trip
3240
Firmware corrupted trip
3600
Watchdog trip
3601
Watchdog trip
3612
Watchdog trip
3A00
Programming corrupted
3B01
Open circuit Motor Trip
3D02
Motor output trip
3D03
Motor output trip
Wartungsanleitung P9-0157-S
Action Bars Comments
Trip
8
Possible controller Fault
Trip
8
Possible controller Fault
Note 1
Note 2
Note 1 - trip or speed limit depends on
programming
Note 2 - trucharge display depends on
programming
Note 1
Note 2
Note 1 - trip or speed limit depends on
programming
Note 2 - trucharge display depends on
programming
Note 1
Note 2
Note 1 - trip or speed limit depends on
programming
Note 2 - trucharge display depends on
programming
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
1
Battery Voltage has dropped below the
operating limits.
Trip
8
Possible Controller Fault
Trip
7
Only trips if "Throttle Operated at Power-Up"
is programmed to "Trip" as recommended
by MDA. Indicates throttle was displaced
when unit was switched on. Check throttle
operation.
No
Ripple
If "Throttle Operated at Power-Up" is
programmed to "Inhibit" then trucharge
display will ripple up and down until throttle
is reset to neutral. No trip will occur in this
mode. Check throttle operation.
Trip
8
Possible Controller Fault - Can also occur if
keyswitch is on, when battery connections
are connected to Battery terminals or
keyswitch is not operating correctly.
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
8
Possible Controller Fault
Trip
2
Check Motor connections and motor
components for open circuits. This will not
occur if the "Brake Fault Detect" is disabled.
Trip
3
Motor output is shorted high, possibly to
Battery positive. Check motor connections
and motor components.
Trip
3
Motor output is shorted low, possibly to
Battery negative. Check motor connections
and motor components.
65 von 68