Electrical installation

The Hoesch whirl tubs are designed for home usage (including hotels, workers' hostels, student hostels, etc.) and meet
the requirements included in relevant EN-VDE norms. An exception is using them for medical purposes.
The electrical installation can be made only by a professional electrician with a proper license.
The electrical installation must be made according to DIN VDE 0100-701 and/or IEC 60364-7-701. Moreover, dur-
ing performing the electric works the national exceptions to the norms and the technical connection conditions of
local power plants should be taken into consideration.
The whirl system is designed to operate with the alternating voltage of 230 V~AC, 50/60 Hz.
The electrical power of the whirl system should be carried from a separate electric circuit and properly protected with
a 10 A fuze, in compliance with the rated power consumption, according to the rating plate. Other users cannot be
connected.
GB
Moreover, install a separate device with a current trip device for the measured differential current ≤ 30 mA for the
whirl tub. The FI B type protecting switch (RCCB) earlier connected separately must meet the requirements of the
DIN EN/VDE norm. The usage of connected switches FI/LS (RCBO) with in-built over-current protection is preferred.
Check the efficiencccy and effectiveness of the current trip device (DCD) on a regular basis.
In the installation placed permanently you should allow for a master switch with a minimum distance between the
contacts of 3 mm, which will be used for general switching off of whirl system and disconnecting it from the power
supply system. Draw the user's attention to a separate possibility of switching off. It is recommended that in situa-
tions when whirl tub is not used for a longer time the whirl installation should be switched off from the power
supply system with the use of the master switch/FI.