Cleaning and maintenance
6.10
➤ Pull the adapter sleeve (fig. 5 4, page 4) off of the plug.
➤ Unscrew the screw (fig. 5 5, page 4) out of the upper half of the housing
(fig. 5 1, page 4).
➤ Carefully raise the upper half of the housing from the lower (fig. 5 6,
page 4) half.
➤ Take out the contact pin (fig. 5 3, page 4).
➤ Replace the defective fuse (fig. 5 2, page 4) with a new one that has the
same rating (8A 32V).
➤ Re-assemble the plug in the reverse order.
6.11
➤ Press the switch pin (fig. 6 2, page 4) downwards so that the transpar-
ent part (fig. 6 1, page 4) of the lamp can be removed at the front.
➤ Replace the light bulb.
I
➤ Press the transparent part of the lamp back into the housing.
7
!
A
➤ Occasionally clean the device interior and exterior with a damp cloth.
16
Downloaded from
www.Manualslib.com
Replacing the plug fuse (12/24 V)
Replacing the light bulb
NOTE
The LEDs in the light bulb must be aligned with the transparent
part of the lamp.
Cleaning and maintenance
WARNING!
Always disconnect the device from the mains before you clean
and service it.
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.