P1 CONNECTOR
P1-5
Green led platform controls enable
P1-7
Red led platform general alarm
P1-8
Red led platform overload alarm
P1-9
AV2 platform audible alarm
P2 CONNECTOR
P2-1
5V - Positive joystick potentiometer
P2-3
-batt- Negative joystick potentiometer
P2-6
Joystick potentiometer signal
P2-7
Positive limit switch power + system led ON
P2-8
EV5 negative control
P2-9
Red led platform flat battery alarm
P3 CONNECTOR
P3-1
Positive platform controls
P3-2
Positive platform controls
P3-3
Speed control "Hare"
P3-4
Backward / Lowering control
P3-5
Forward / Lifting control
P3-6
Platform drive selection
P3-7
Platform Lifting / Lowering selection
P3-8
Right steering control
P3-9
Left steering control
P3-10
Load control signal
P3-12
"Dead-man" control
P4 CONNECTOR
P4-1
Positive ground controls
P4-4
Ground lowering control
P4-5
Ground lifting control
P4-6
M1 limit switch signal (contact closed with platform
lowered)
P4-7
MPT limit switch signal (contact closed with pot-
hole guards lowered)
P4-11
System signal active
P4-12
Flat battery signal
P5 CONNECTOR
P5-1
line remote switch TLR control and hour-meter
signal
P5-2
EV2 solenoid valve control – Forward drive
P5-3
EV3 solenoid valve control – Backward drive
P5-5
Rotating beacons control
P5-6
EV8 solenoid valve control – Left steering
P5-7
EV5 solenoid valve positive control - Lowering
P5-8
EV9 solenoid valve control – Right steering
P5-9
EV10A / EV10B solenoid valve control – Fast drive
P5-10
AVI audible alarm
ELECTRIC DIAGRAM STANDARD MACHINES
045.08.011 – 045.08.012
RESTYLING
Uso e manutenzione – Serie X – XS E RESTYLING
P5-11
EV4 solenoid valve control – Lifting
P5-12
EV11 solenoid valve control – By pass
DEVICES AND SHEATHS KEY
CB
Battery charger
CC
Load control
CCT
Ground controls cable
CCP1
Platform controls cable – sheath 1
CCP2
Platform controls cable – sheath 2
EV2
Forward drive solenoid valve
EV3
Backward drive solenoid valve
EV4
Lifting solenoid valve
EV5 A/B
Lowering solenoid valve
EV8
Left steering solenoid valve
EV9
Right steering solenoid valve
EV10
Fast drive solenoid valve
A/B
KL
Horn
+KL
Horn positive control
M1
M1 limit switch (contact closed with platform
lowered)
MPT1
MPT limit switch (contact closed with pot-hole guard
lowered)
MPT2
MPT limit switch (contact closed with pot-hole guard
lowered)
RCB
Battery charger relay
SP1
Ground emergency switch
SP2
Platform emergency switch
TLR
Line remote switch
( - )
0V – Negative battery
-B
0V – Negative battery
5AB
Jumper between EV5 and EV8 sheaths
+KL
Platform horn control
MPT
Jumper between MPT1 and MPT2 sheaths
+RCB
+24V – Positive battery from battery charger relay
SP1
Positive from ground emergency button
SP2
Positive from platform emergency button
1
Battery charger
2
Battery
3
Quick disconnection plug
4
Power fuse
5
Line remote switch
6
Electric pump
7
Controller
Pag. 127