9) Use the opening angle of the gate to determine the correct installation dimensions (see also Figure 7)
Attention! A dimensions and B dimensions must be strictly adhered to in the specified range of
130 - 190 mm (see Fig. 7). Otherwise, system learning will not be possible.
Result: Control boards stops the motors during the learning run or motors reverse during
Porte 150
10) "C" value is 94 mm
11) "D" can be easily measured
12) "A" = "C" + "D"
13) The value "B" can be determined by means of "A" and the opening angle of the gate leaf.
Example: If "A" is 160 mm and the opening angle is 100°, then the distance "B" should be
about 190 mm.
** Please make sure that the dimensions "B" and "A" on both sides
are approximately equal or as close to equal to ensure a smooth
operation.
130
140
A B
130
>120°
140
150
160
170
180
190
running of the gate and to protect the motors.
Figure 6 (Aerial View)
Figure 7
150
160
170
180
110°~120°
100°~110°
90°~100°
20
190