10.3 Befehlssatz
P ... Poll, B ... Burst, S ... Set, N ... Notification
FORMAT SET
Description
Poll parameter
Set parameter
Set without Save
FORMAT RESPONSE
Description
Acknowledge
Error message
COMMAND LIST
Description
Device adjustment
gain**
Device adjustment
offset **
Device special Info.
Emissivity internal
Valley hold time
Average time
Top of mV range
Sensor/head ambient
Relay alarm output
control
Bottom of mV range
Output voltage***
CM
Char Format P S Example
?
?X
=
X=...
#
X#
Char Format P S Example
!
!XXX
*
Char Format P S Legal values
DG
n.nnnn
DO
nn.n
DS
XXX
E
n.nnn
F
nnn.n
G
nnn.n
H
nnnn.n
I
nnn.n
K
n
L
nnnn.n
O
nnn
Rev. B 06/2011
?T
E=0.85
E#0.85
!T020.0
*Syntax error
0.8000 ... 1.2000
-20.0 ... +20.0°C
z.B. !DSRAY
0.100 ... 1.100
0.000 ... 998.9 s
(999 = infinite)
0.100 ... 999 s
0 ... 500°C
In current scale (°C/°F)
0=Alarm Off
1=Alarm On
2= Target, normal open
3= Target, normal close
4= Head, normal open
5= Head, normal close
6= Over current protect*
-20 ... 480°C
0-100=% of full range
255=controlled by unit
Anhang
Factory default
1
0
DSRAY
0.95
0
0
500
-20
44