Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Qlima H 724 Gebrauchsanweisung

Ultraschall-luftbefeuchter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
level 3. Temperature and humidity will be displayed. Press again to shut off the
machine power.
2.
Mist: Press the 'Mist' key to switcht the mist level from level 1 till 5. The set value
will be shown on the display.
3.
Humidity: Press the 'Humidity' key to adjust the humidity from 40% till 90% in
steps of 5%. With the humidity set the unit will automatically start and stop to
reach the requested humidity level.
4.
Timer: Press the 'Timer' key to set up the timer from 1 till 12 hours. The set time will
be shown in the timer display. When the time runs out the unit will shut down.
5.
Anion: Press the 'Anion' key to turn on/off the ioniser function, the anion indicator
will light up when this function is turned on.
6.
Auto: Press the 'Auto' key to turn on the auto mode and the unit will be set to
70% humidity automatically. The display and signal indicators will also be dimmed
which makes this mode suitable for sleeping. Press any key to wake up the screen
and turn off this mode.
G
ATTENTION
When the unit runs out of water and the tank is empty it will stop humidifying
immediately but the fan will continue for 10s to assure the unit is blown dry. In
the mean time the buzzer signals 3 times, when no water is added the unit will
completely shut down after 15s and the empty tank indicator will light up red.
4. WARNINGS
Allow the device to reach room temperature for at least 30 minutes before initial use.
The water temperature should not exceed 40°C. Always use clean water.
Do not add any liquids (like etheric oils) other than clean water to the tank.
Don't place the unit near a heat source or in direct sunlight and keep 2m distance from
furniture and electrical appliances.
Use the humidifier at room temperatures (5°C to 40°C) and at a relative humidity of <80% RH.
When running or filled do not move the unit.

5. MAINTENANCE

G
WARNING
Before clean and maintain this machine, do turn it off and pull out the plug.
Make sure machine is powered off to avoid electric shock.
CLEAN OSCILLATING PLATE
1.
Take out water tank of humidifier.
4
37

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis