Herunterladen Inhalt Inhalt Diese Seite drucken

Bestway LAY-Z-SPA Bedienungsanleitung Seite 21

Vorschau ausblenden Andere Handbücher für LAY-Z-SPA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 81
• You can keep the spa on during winter when the temperature is lower than 6°C(42.8°F).
The Freeze Shield™ system automatically keeps the water temperature between
6°C(42.8°F) and 10°C(50°F), and it will prevent the water from freezing.
Important: If the water temperature is below 6°C(42.8°F), the spa heater must always
be on. In this mode, the Freeze Shield™ system can keep the internal temperature
between 6°C(42.8°F) and 10°C(50°F) to prevent damage, such as water freezing in the
pipes or the circulation system.
Important: If the Freeze Shield™ system isn't working, alarms will pop up on the spa.
Be sure to check the status of your spa if the outdoor temperature is below 6°C(42.8°F).
In case of a long-term absence from home when there is a risk of temperatures falling
below 6°C(42.8°F), we strongly suggest disassembling the spa and storing it following
the storage procedure.
• Any damage as a result of using the spa in these conditions is the responsibility of the
customer. Do not use the spa when the ambient temperature reaches -10°C(14°F).
HEATING RESET
When using the Lay-Z-Spa for first time, or after a long period of
inactivity, be sure to press the reset button on the pump using a
small and thin object.
If the temperature on the control panel (or the water temperature)
has not changed 4-5 hours after activation of the heating system,
use a thin object to press the RESET BUTTON, and restart the
heating system.
IMPORTANT: The heating system will not operate if the outside
temperature is above 40ºC (104 ºF) or if the Lay-Z-Spa is under direct sunlight.
Under these conditions, please wait until a cooler time of day before pressing the
RESET BUTTON with a thin object and restarting the heating system.
IMPORTANT
To reach 40°C (104°F), the heating duration required is based on the starting water
temperature and ambient temperature, the data below is purely for reference. To
display the current water temperature, run the filter system for at least a minute.
Ambient Temperature
10ºC(50ºF)
15ºC(59ºF)
20ºC(68ºF)
25ºC(77ºF)
30ºC(86ºF)
• Be sure to cover the spa with the
spa cover whenever the heating
function is activated. Leaving the
spa uncovered will increase the
heating duration required.
• When the spa is assembled with
water, do not switch off the spa
heater if the temperature is lower
than 6ºC(42.8°F).
Power Rate
220-240V AC,
50Hz, Single Phase
2,050W at 20ºC
Water Temperature
10ºC(50ºF)
15ºC(59ºF)
20ºC(68ºF)
25ºC(77ºF)
30ºC(86ºF)
Heat Element Power
2,000W at 20ºC
Set Temperature
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
40ºC(104ºF)
Filter Pump Power
Massage Tube Power
50W
21
RESET
Heating Duration
18.5h - 21.5h
15h - 18h
11.5h - 14.5h
8.5h - 11h
5.5h - 7.5h
Jet Pump Power
800W
1200W

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis