The wash program continues, and the display continues to show the error until the operator
touches the Signal Cancel button.
Too Long to Cool
4.1.7.
C
ooldown Time Configu
this time if necessary.
Low Water Pressure: Do a check of the cold water pressure and volume to the machine.
Cooldown Valve Malfunctioned: Do a check of the cooldown valve for proper o
Temperature Circuit Malfunctioned: Do a check of the temperature probe and the analog-to-
digital board for proper opera
The wash program continues, and the display continues to show the error until the operator
touches the Signal Cancel button.
Check Temperature Probe(s)
4.1.8.
The Probe is Disconnected: Check the position of the probe and the connections.
The Probe Malfunctioned: Disconnect the probe and measure the resistance between the leads.
T
he resistance between the leads should be between 2K and 35K Ohms. The resistance between
either lead and the ground should be infinite.
The temperature probe detected a temperature below 32° F (0°C) or above 230°F (110°C). If the
probe connections are found good, d
between the leads is from 2K to 35K Ohms. Also, do a check that the resistance be
lead and ground is infinite. The wash program continues, and the display continues to show the
error until the operator touches the Signa
Level Made After Drain
4.1.9.
Drain Blocked: Do a check that the drain valve and drain outlet are clear of debris.
Transducer Tube Blocked:The tube from the shell to the pressure transducer may be blocked.
Check the tube and remove lint or other obstructions.
Drain Valve Malfunctioned:The drain valve or drain valve solenoid may have malfunctioned.
Use the schematic diagram to find the
If a slow drain caused the error, the error clears when the transducer senses that the water l
the cylinder is less than the configured low water level.
Serial Communic
4.1.10.
Board Failure: A peripheral board in the control box cannot communicate wit
b
oard.
The controller stops basket rotation and waits for the serial communications to resume. Touch the
Signal Cancel button to en
Failed Speed Sensor
4.1.11.
Speed Sensor Failure: The sensor that verifies t
st
opped is not working. The processor board must receive a signal from the speed sensor at least
red too Short: Do a check of the configured cooldown time. Increase
tion.
isconnect the probe and do a check that the resistance
l Cancel button.
problem.
ation Failure
d the wash program.
hat the device used to determine if the basket has
39
Chapter 4. Troubleshooting
peration.
tween each
evel in
h the processor
PELLERIN MILNOR CORPORATION