Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Connections; Plug In Receiver - V2 CITY1-EVO Kurzanleitung

Digitale steuerung (230v) für flügel und schiebetore
Vorschau ausblenden Andere Handbücher für CITY1-EVO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 74

5.1 - ELECTRIC CONNECTIONS

m
WARNING: The installation of the unit, safety
devices and accessories must be carried out when the
power supply is disconnected
BEFORE PROCEEDING WITH THE ELECTRICAL
CONNECTIONS, READ CAREFULLY THE CHAPTERS
DEDICATED TO THE INDIVIDUAL DEVICES AVAILABLE IN
THE PAGES THAT FOLLOW.
L1
Antenna
L2
Antenna shielding
L3
START - Opening control for the connection of
control devices with N.O. contact
L4
START P. - Opening controls for pedestrian access for
the connection of control devices with N.O. contact
L5
STOP - Stop command. N.C. contact
L6
Common (-)
L7
FOT1 - Photocells type 1. N.C. contact
L8
FOT2 - Photocells type 2. N.C. contact
L9
COS1 - Safety edges type 1. N.C. contact
L10
COS2 - Safety edges type 2. N.C. contact
L11
Common (-)
REFER TO THE COMPLETE MANUAL TO CONFIGURE THESE
DEVICES
E1
FCA1 - Open limit switch
motor M1
E2
FCC1 - Close limit switch
motor M1
E3
FCA2 - Open limit switch
motor M2
E4
FCC2 - Close limit switch
motor M2
E5
Common (-)
Z1
Power output 24 Vac for photocells and other
accessories
Z2
Common for accessories power supply
Z3
Photocell/optical edge TX power supply for
functional test
Z4 - Z5
Lock 12V
Z5 - Z6
Low voltage light (12Vdc - 3W)
H1 - H2
H3
H4
H5
H6
H7
H8
L
N
RM
ADI 2.0
USB
OVERLOAD
MAINS
F1
J1 - J2 - J3
Encoder
motor M2
Encoder
motor M1

5.2 - PLUG IN RECEIVER

CITY1-EVO is suitable for plugging in a Personal Pass MR receiver.
m
removable modules.
MR1 module receiver is provided with 4 channels and each of
them is suitable for a command of CITY1-EVO control unit::
• CHANNEL 1
• CHANNEL 2
• CHANNEL 3
• CHANNEL 4
The transmitter codes can be stored in two ways:
1. By pressing the P1 button on the MR receiver (read the
instructions supplied with the receiver)
2. Using WINPPCL software: to run the program you need to
connect a PC to the control unit. The connection can be made
via USB using a standard USB cable.
- 18 -
Flashing light 230 / 120 Vac - 40W
Motor M1 (OPENING)
Motor M1 (COMMON)
Motor M1 (CLOSING)
Motor M2 (OPENING)
Motor M2 (COMMON)
Motor M2 (CLOSING)
Power phase 230V / 120V
Neutral 230V / 120V
MR receiving modules
ADI 2.0 interface
USB connector
It shows that there is an overload on accessories
power supply
It shows that the control unit is power supplied
5 A (230V versions)
8 A (120V versions)
Connectors for the LOW ENERGY module
WARNING: Pay attention to the way you connect the
g
START
g
PEDESTRIAN START
g
STOP
g
COURTESY LIGHT

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis