Short description of some selected functions
(all functions are described in the full version of the SQ610RF manual):
1. DISPLAY TEMP RESOLUTION:
User can temperature set by steps (every 0,5°C or 0,1°C).
2. CONTROL ALGORITHM:
are: ITLC for Underfloor Heating / Radiators / Electrical Heating (that's advanced algorithm for precise
maintenance of room temperature), hysteresis +/-0.5°C or +/-0.25°C, THB Actuator (option recommended
for systems with THB auto balancing actuators).
3. S1/S2 INPUT:
A floor sensor, an external temperature sensor or an occupancy sensor can be connected
to the S1/S2 input of SQ610RF. Additionally, by connecting a NO type of ON/OFF voltage-free contact, you
can use this input as a OneTouch rules trigger (programmed in the Salus Smart Home app) or as a Heat/
Cool changeover.
4. VALVE PROTECTION:
function helps to prevent the actuators stuck).
5. MIN TURN OFF TIME:
cooling more often than specified in this parameter).
6. OPTIMISATION FEATURE:
makes thermostat most cost effective (in combination with ITLC control algorithm).
7. COMFORT WARM FLOOR: This function helps to keep the floor warm, even if the room is warm enough
and there is no need to turn on the heating. User can select 3 levels of warm floor feature. Please note it is
not an economy feature, as your heating system may be ON even if there is no heating demand from the
room thermostat. It is COMFORT feature which keeps your floor warm all the time.
8. DEVICE INFORMATION: In this menu user can check: Software Version, Battery Level, RF range value,
Paired devices or also user can activate Identification mode.
9.
FACTORY RESET: Here you can RESET your device to factory settings. After successfull reset
device will be removed from ZigBee network and you will need to add / pair your device again.
This function determines the resolution of the displayed temperature -
This function defines how to control the room temperature. Available options
This function activates all actuators once a week for 5 minutes (in summer, this
Minimum switch-off time (thermostat will not send the signal for heating/
Optimum Start and Optimum Stop functions are energy saving feature that
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis