Herunterladen Diese Seite drucken

Grohe 33 106 Montageanleitung Seite 5

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is not possible.
Specifications
x
Flow pressure min. 0.5 bar / recommended 1 - 5 bar
x
Operating pressure
x
Test pressure
If static pressure is greater than 5 bar, fit pressure
reducer.
Avoid major pressure differences between hot and
cold water supply.
x
Flow rate at 3 bar flow pressure:
x
Temperature
Hot water inlet
Recommended
x
Water connection
Installation
Flush pipes thoroughly!
Installation and connection, see fold-out page III,
Fig. [1].
When assembling, the waste rod (A) has to be placed
into the body.
Fit pop-up waste set (28 910), see fold-out page II.
Seal plug-hole rim!
Open cold and hot-water supply and check con-
nections for leakage!
Check fitting for correct operation, see fold-out
page III, Fig. [2].
Caution
Do not lift the lever, the security mixer opens by turning
the lever.
The water temperatur increses on turning from left to
right from cold- through mixed- to hot water.
Temperature limiter
On delivery, the temperature limiter (fitted as standard)
is inoperative.
For commissioning see "Replacing the cartridge" point
1 to 4.
Remove temperature limiter (E) and, depending on the
maximum temperature required, turn clockwise (to
increase temperature) or anticlockwise (to reduce
temperature) and refit, see Fig. [3] and [4].
max. 10 bar
16 bar
approx. 8 l/min
max. 80 °C
(energy saving) 60 °C
hot - left
cold - right
Flow rate limiter
This fitting is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see "Replacing the cartridge" point
1 to 4, Figs. [3] and [5].
Mounting of lever, see Fig. [6].
After setting of flow and temperature the lever is
replaced relative to the marking A on the cartrige. The
lever will be positioned in such a way that the fixing
screw (C) is screwed against the face marked A.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Shut off the hot and cold water supply!
I. Replacing the cartridge, see Fig. [3].
1. Turn lever (D) left (mixer closed).
2. Lever out plug (B).
3. Loosen set screw (C) with 4mm socket spanner.
4. Pull off lever (D).
5. Pull off temperature limiter (E).
6. Remove screws (G) and detach complete
cartridge (H).
7. Change either the complete cartridge (H) or
seals (H1).
Observe the correct installation position.
Make sure that the cartridge seals (H1) engage in
the grooves on the housing. Fit screws (G) and
tighten evenly and alternately.
II. Unscrew and clean flow straightener (13 960), see
fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
2

Werbung

loading

Diese Anleitung auch für:

33 10832 365