LOGGER INTERVAL SETTING:
Press SET button in normal mode.
HIST appears on the display.
The recording interval indication starts flashing
next to the symbol REC.
Default interval 0:15 HR:MIN corresponds 15
minutes.
The "+" or the "-" button allows you to select the
recording intervals listed below:
1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 2 hrs, 3 hrs and 6
hrs.
This function allows you to set the interval in which the
instrument records the data sets. The instrument automatically
creates a data set in the corresponding interval. A data record
is a snapshot of the temperature and humidity values as well as
The recorded data sets can be called up in history mode.
MAX/MIN VALUES AND THE CURRENT DEW POINT
Press OK/MAX/MIN button in normal mode.
MAX appears in the display and the highest
humidity is displayed.
Press the button again.
The highest temperature is displayed.
Press OK/MAX/MIN button again.
MIN appears in the display and the lowest humidity
is displayed.
Press the button again.
The lowest temperature is displayed
Press the button again.
DEW appears in the display.