Maintenance of Micro Mesh Stainless Filter (continued)
Attach the micro mesh stainless filter.
7
• Align the filter with the top face of the indoor unit, and then slide and push it in.
(The shape of the left and right filters is the same.)
• Tighten the left and right filter locks to the indicated direction.
8
Attach the front panel.
1 Insert the shaft of the left arm along the step on the unit into the hole.
2 Securely insert the shaft of the right arm along the step on the unit into the hole.
3 Make sure that the front panel is securely attached.
4 Attach the temperature display box and WIFI adapter.
Arm
Hole
9
Close the front panel.
• Pull it downward.
Push the both ends of the front panel first and then its center until it clicks.
CAUTION
• If the front panel is loose, it may come off and drop.
• When opening the front panel upwards, please do not use excessive force.
If the front panel comes off the device, this may cause it to malfunction.
10
Turn on the circuit breaker.
CAUTION
• Improper installation of the micro mesh stainless filter could result in malfunction. Filter cleaning
operation can not be performed properly and the
• Do not operate the air conditioner without the micro mesh stainless filter.
Dust goes in the gap of the heat exchanger as well as inside the appliance and may cause unpleasant smell
on the heat exchanger or could result in malfunction.
• Be extra careful not to cut your hand with the fin of the heat exchanger when removing and
reattaching the micro mesh stainless filter.
Neck
1
(FILTER CLEAN)
- 10 -
F
ilter locks
2
Arm
Hole
indicator blinks.