18
- Descaling the soleplate: if you do not descale your steam
generator regularly, scale may build up on the soleplate.
You can remove scale by following the instructions below:
1
Descale the steam generator before you clean the
soleplate (see section 'IMPORTANT - Descaling the
steam generator').
2
Tilt the steam generator and pour 500ml distilled water
into the opening. Reinsert the EASY DE-CALC knob
and turn the knob clockwise to fasten it.
3
Press the on/off button and wait for 5 minutes.
4
Put a piece of thick cloth on your ironing board. Place
your iron on the cloth, press and hold the steam trigger.
While pressing the steam trigger, slowly move the iron
back and forth across the cloth until no water comes
out anymore or when steam comes out.
Hot, dirty water comes out of the soleplate.
5
Switch off the steam generator and let it cool down for
2 hours.
6
Remove the EASY DE-CALC knob and let the water
flow into a cup. Reinsert the EASY DE-CALC knob and
turn the knob clockwise to fasten it.
7
Repeat steps 2 to 6 of this cleaning procedure.