OPERATION

After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board and the EUROLITE IR-Remote 2 remote control or in DMX-controlled mode via
any commercial DMX controller.
Enter the menu by pressing the MODE-button. Browse through the menu by pressing UP or DOWN. Press
ENTER in order to select the desired menu. You can change the selection by pressing UP or DOWN. Press
ENTER in order to confirm. You can leave every mode by pressing MODE. The functions provided are
described in the following sections.

Menu structure in Stand Alone Mode

Mode
DMX
CHANNEL
SLAVE
MANUAL
IR REMOTE
FIXTURE ID
DIMMER
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Press the MODE button so many times until
SLAVE is indicated in the display. Confirm with the ENTER button.
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode. The interconnected devices will now operate in sync.
Fixture ID
Service PIN
The password for this function is „050".
Downloaded from
www.Manualslib.com
Display
ADDR: 001 ~ 512
DMX address setting
CH:01
Setting DMX channel mode
CH:02
SLAVE
Slave setting
Dim: 00 - 99
Dimmer with increasing brightness
F: 00 - 99
Strobe with increasing speed
Control via IR remote
ON
:enable
Control via IR remote
OFF
:disenable
Password 000-255
Password: 050
RDM ID 0000-9999
RESPON01
Dimmer speed 1 = LED
RESPON02
Dimmer speed 2 = Halogen