Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting Options - Lightmaxx Vega Beam 1.0 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH

Mounting options:

ATTENTION: Install the device outside the audience's range.
It must be ensured that the intended mounting point has sufficient load-bearing capacity. The
projector's suspension devices must be designed and dimensioned to withstand 10 times the
payload for 1 hour without permanent damaging deformation.
The device must always be protected by a second independent fuse that complies with the
applicable regulations.
There must be no persons underneath the device when it is mounted or is maintained.
The unit must be operated at least 0.5m from the nearest flammable surface.
Hanging installation may only be carried out by qualified personnel. The permissible load-bearing
capacity and the applicable regulations for event technology must be observed. Under certain
conditions, acceptance by experts or institutions is necessary.
It must be ensured that the device is safely mounted before it is put into operation.
If the unit is to be suspended from the ceiling or from high beams, etc., it is always necessary to
work with truss systems. The unit must never be fixed in the room so that it can vibrate freely.
The device can be placed directly on the floor or in any position in the trussing without changing
its functional properties.
The unit is equipped with two quick-fit Omega suspension brackets. These are screwed to the
unit and provide a mounting hole for common clamps. When mounting this device on a crossbar,
make sure that the clamp is screwed to the Omega suspension brackets using an M10 screw and
nut. Insert the two quick-release fasteners of the respective Omega support bracket into the
openings provided on the underside of the unit. Tighten the quick-release fasteners clockwise
until they stop.
Always secure the device with a suitable safety rope when it is mounted overhead (mounting
height >100 cm).
Only safety ropes and quick links in accordance with DIN 56927, shackles in accordance with
DIN EN 1677-1 and BGV C1 chain binders can be used. The safety ropes, quick-connect links,
shackles and chain binders must be sufficiently dimensioned and correctly applied on the basis of
the latest industrial safety regulations (e.g. BGV C1, BGI 810-3).
Hook the quick-release link into the hole provided in the base plate. Guide the safety rope over
the crossbar or a secure fixing point. Hook the end into the quick-release link and tighten the
locking nut firmly.
The maximum drop distance must not exceed 20 cm.
A safety rope that has been subjected to a fall load or has been damaged may no longer be used
as a safety rope.