a) The room must be fitted with a ventilation system which vents smoke and gases from
combustion to the outside. This must be done by means of a hood or electric ventilator that
turns on automatically each time the hood is operated.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed for proper combustion. The flow of
air for combustion purposes must not be less than 2 m³/h per kW of installed capacity. The
supply of said air can be effected by means of direct influx from the outside through a duct
with a inner cross section of at least 100cm² which must not be able to be accidentally
blocked. Those appliances which are not fitted with a safety device to prevent the flame from
accidentally going out must have a ventilation opening twice the size otherwise required, i.e. a
minimum of 200 cm² (Fig. 3). Otherwise, the room can be vented indirectly through adjacent
rooms fitted with ventilation ducts to the outside as described above, as long as the adjacent
rooms are not shared areas, bedrooms or present the risk of fire (Fig. 4).
Adjacent Room
Fig. 3
Examples of ventilation holes for comburant air
c) Intensive and prolonged use of the appliance may necessitate supplemental ventilation, e.g.
opening a Window or increasing the power of the air intake system (if present).
d) Liquidified petroleum gases are heavier than air and, as a result, settle downwards. Rooms in
which LPG tanks are installed must be fitted with ventilation openings to the outside in order
to allow the gas to escape in the event of a leak. Therefore, LPG tanks, whether empty or
partially full, must not be installed or stored in rooms or spaces below ground level'(cellars,
ect.). It is also a good idea to keep only the tank currently being used in the room, making
sure that it is not near sources of heat (ovens, fireplaces, stoves, etc.) that could raise the
internal temperature of the tank above 50ºC.

Installation of built-in hobs

The gas hobs are prepared with protection degree against excessive heating of type X, the
appliance can therefore be installed next to cabinets, provided the height does not exceed that of
the hob. For a correct installation of the cooking hob the following precautions must be followed:
a) The hob may be located in a kitchen, a ketone/diner or bed sitting room, but not in a bathroom
or shower room.
b) The furniture standing next to the unit, that is highe1 than the working boards, must be placed
at least 110mm from the edge of the board.
Directly to the Outside
Room to be Vented
Fig. 4
Enlarging the ventilation slot between
window and floor
26