4.
Closed
INSTRUCTIONS During the first heating, check that the air
control lever of the fireplace is moving as it should. When
lighting the fire, the air control lever is in the ignition position, and
when the load is burning properly, the fireplace controller moves
the air control lever to the combustion position and finally, when the
embers have partially or fully died down, to the closed position. In
this way the system is working properly.
DAMPER TOO SOON!
When the fireplace door is opened for more than 10 seconds, the
air control lever begins to move. If the door has been open for less than
10 seconds, the system will always return to the previous state. When
you have added fuel and ignited it, close the door. After a moment, the
air control lever will move to the ignition position. If the ignition has not
been done or it is unsuccessful, the lever will go to the closed position
after about half an hour. When the load is lit, the lever will begin to
move on the basis of the fireplace temperature information, starting
from the ignition phase position and moving to the combustion phase
position. When the combustion has progressed to the embers phase,
the lever will begin to return gradually to the embers phase position.
When the embers have burnt down to a suitable size, the controller
will display an add signal in the user interface. Add firewood according
to the device's instructions until 80% of the optimal heat capacity is
reached. At this point, the controller will notify you about stopping
the heating. The controller will wait for addition of fuel for about 10
42
AIR CONTROL LEVER POSITIONS OF THE FIREPLACE
Lighting or embers
minutes before moving on to the next phase. When fuel is no longer
added, the heat capacity will rise for approximately a further 15–25
percentage units. If the controller displays the add signal close to 70–
80% heat capacity, add only a small additional load to the fireplace.
You can stop heating before receiving the notification if you notice
the heat is sufficient in the room. When finishing the heating, stoke
DO NOT CLOSE THE FLUE
the embers on the grate to help the embers burn down completely.
Finally, when the fireplace temperature has fallen to a sufficient level,
the controller will close the air control lever. Closing the flue damper
is not absolutely necessary, because the controller will close the air
control level tightly so that air will not pass through the fireplace.
If, when heating the fireplace, the heat capacity exceeds 120%,
this will result in a state of overheating in which the air control lever
will attempt to cool down the fireplace. Overheating must be avoided,
and no wood may be burned during overheating.
fireplaces the controller door switch is the same side as the air
control lever and SENSO works correctly only using this door.
Note: If the controller displays an add signal at the wrong
time, for example after adding a load or after ignition, check
the functioning of the fireplace. A situation like this may occur
if you add wood too late or the wood has not ignited properly.
NEVER ADD PELLETS TO A HOT FIREBOX, even if the
controller displays the add signal.
check how the pellets are burning, and stoke them on the grate. Just
Combustion or addition
add some more wood if necessary.
pellets for combustion, always remember to change the fuel
type to PELLET in the application menu.
selected as the fuel type, the fireplace will not work properly and may
give false instructions.