USING THE SMART DEVICE APPLICATION
Status information in figures
• Heat capacity "%"
• Firebox temperature "°"
• Heat capacity temperature "°"
• Room temperature "°"
• Flue draught "Pa"
• Momentary heating capacity, "kW", is a calculated unit, which has been set
as a constant as the heating capacity of an insulated fireplace. The calculated
capacity does not provide an accurate value and instead gives an indicative
heating capacity. If the fireplace has no insulation and you wish to know the
calculated capacity of the uninsulated fireplace, contact the Tulikivi maintenance
service where they can give you instructions on adjusting the heating capacity
of the fireplace controller using the smart device app.
Descriptions of combustion phases/symbols
Ignition phase (Text: Ignition)
The controller lets more air through the grate for ignition.
At the ignition phase, the controller waits for approximately
30 minutes before it moves on to the closing phase.
Combustion phase (Text: Combustion)
Secondary air at maximum, a small amount of grate air.
The controller moves on to the combustion phase after
successful ignition or adding of fuel.
Adding more wood (Text: Add more wood)
The controller will wait for addition of fuel for about
10 minutes before moving on to the closing phase.
Embers phase (Text: Embers)
Full grate air, the embers burn down quickly. Lasts as longs as
it takes for the fireplace to cool down and for the embers to have
fully burned down.
Standby mode (Text: Standby mode)
Air control lever closed.
Door open phase (Text: Door open)
Notifies when the door is open.
Fireplace's name information
Info
Shows the descriptions
of information on the
home page.
Statistics
At the bottom of the display, click on the buttons
or swipe sideways to access the respective menus
of the statistics, home and settings pages.
Home page
Settings
pages 9-10
Heat capacity circle
One bar corresponds to 2% heat capacity increase.
Mode information and combustion instructions are
provided inside the heat capacity circle.
By keeping an eye on the heat capacity, you can
learn what the suitable amount of heating is in the
circumstances prevailing each time.
The fireplace does not necessarily require optimal
combustion in all circumstances, but by monitoring
the heat capacity and suitable temperature, you
learn what the optimal use of the fireplace is.
page 8
STATISTICS
Last 10 combustions
AV. TEMPERATURE
DURATION (H)
35