7. Basic settings/operation

Use the MENU button [a] to scroll through the available menus. Use the ENTER button [b] to select a mode
or accept a value.
Change values with the
Notes:
Keep the
[c] or
Exit the menu setting at any time by pressing the HISTORY button [f] or simply wait 30s until the
receiver automatically returns to normal display.
When not in setup, press the HISTORY button [f] to switch on the backlight for ±10s.
All settings can also be made through the software (see §9 PC connection)
Refer to the table below for an overview of the menu and setting options.
MENU
Mode
Time
LCD contrast
Time zone
Time format
Manual time
setting
Date
display mode
date/month format select between DD-MM or MM-DD format (dM or Md)
year
month/date
alarm time
Pressure
graph scale
history
Pressure
pressure display
mode
pressure unit
relative pressure
high alarm
low alarm
reset max
reset min
Weather
Refer to §8.2 for more information.
forecast
tendency
tendency
pressure threshold set threshold between 2 ~ 4 hPa (default = 2hPa)
storm threshold
Indoor
high alarm
humidity
low alarm
reset max
reset min
02.02.2011
WS3080
[c] or
[d] button
[d] button pressed to increase setting speed.
Description
set LCD contrast 0~8 (default = 5)
set applicable time zone:
-1 = GMT / 0 = GMT+1 / 1 = GMT+2 ... (default = 0)
set time format 12h/24h (default = 12h)
set hour an minutes manually
select the desired display mode:
day-month-seconds (default) / day-month-day of the week / alarm time
set year
set month and date
set the alarm time
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
set the bar graph scale to 12h or 24h for pressure history
select between relative (rel) or absolute (abs) pressure (default = absolute)
select pressure unit: hPa, mmHg or inHg (default = hPa)
set the relative pressure level (only when relative pressure display mode was
selected)
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
set the low alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
(both pressure [2] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both pressure [2] and min icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
select tendency
set threshold between 3 ~ 9 hPa (default = 4hPa)
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
set the low alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
(both indoor humidity [7] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both indoor humidity [7] and min icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
appears.
appears.
appears.
appears.
appears.
7
©Velleman nv

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis