INSTRUCTION MANUAL FOR DISHWASHERS
The machine is equipped with a self-diagnosis system that can detect and signal a series of
malfunctions.
CAUTION! Turning the machine off and then back on resets the signal, which will appear
subsequently only if the problem has not been resolved. If the signal persists, contact a qualified
technician.
Message displayed
"
RESET ATTEMPT"
"
"
SAFE
"
"
SAFE LEVEL
"
"
NO SALT
"
"
REGENERATION ON
Rinse not performed (Only versions CRP-SP). This signal appears at the end of the
cycle if the working level in the tank is not correctly restored. Check whether the
plumbing connections are correct, and that the water supply cock is open. If the problem
persists, contact technical service.
Water drainage anomaly. Water does not drain or drains abnormally. Check to see if
the overflow has been removed. Check the drain tube is not bent or crushed, and that
none of the filters are clogged. Run another drain cycle. If the problem persists, contact
technical service.
Boiler temperature reset anomaly. The boiler temperature reset has not occurred
within the time limits set forth in the wash cycle. Turn the machine off and then back on
and run another cycle. If the problem persists, contact technical service.
Tank filling time out: the tank has not filled.
Check whether the plumbing connections are correct, and that the water supply cock is
open. Check the presence of the overflow. If the problem persists, contact technical
service.
Tank thermometer anomaly. (Probe open) The machine does not measure the
temperature in the tank. Turn the machine off and then back on. If the problem persists,
contact technical service.
Tank thermometer anomaly. (Probe shorted out) Interrupt the programme in
progress, and shut off the dishwasheril. Turn it back on after a few minutes and start the
cycle again. If the problem persists, contact technical service.
Boiler thermometer anomaly. (Probe open) The machine does not measure the
temperature in the boiler. Turn the machine off and then back on. If the problem
persists, contact technical service.
Boiler thermometer anomaly. (Probe shorted out) Interrupt the programme in
progress, and shut off the dishwasher. Turn it back on and start the programme again. If
the problem persists, contact technical service.
Boiler fill time out: failure of boiler to fill. Rinsing cannot be performed.
Check that the water supply tap is open.
Run another complete cycle.
If the problem persists, disconnect the electricity and contact technical service.
Electromechanical safety: the safety thermostats of the boiler or tank have tripped, or
the tank safety pressure switch has intervened. Contact a technical service centre.
Incorrect tank level: the tank pressure switch has detected a level of water in the tank
that is too high or too low. Contact a technical service centre.
Salt tank empty.Add salt (Par. 4.9 ).
Resin regeneration in progress; the wash cycle may take longer than usual.

Chap 6 SELF-DIAGNOSIS