Overview Presentation; User Interface Area - Cristec YPOWER 12V/16A Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für YPOWER 12V/16A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37
2.2
O
VERVIEW PRESENTATION
The chargers are divided into 2 zones :
The user interface zone
The energy conversion zone (all maintenance in this area is forbidden except with CRISTEC authorization, under
penalty of warranty termination)
Fixing of the charger is made by 4 x M5 round head screws (screw head diameter less than 10 mm).
Center distance : see corresponding drawing in the appendices 3 to 5 depending on model.
Mounting by 4 x M5
round head screws
CONNECTIONS :
AC input terminal : WAGO type
WINSTA reference 770-813
2.3
U
SER INTERFACE AREA
Chargers YPO 12-16, 12-25 and 24-12 - See appendix 1
Chargers YPO 12-40, 12-60, 24-20 and 24-30 - See appendix 2
Terminal for temperature probe
STP-NEW-2.8 (option)

User interface area

Opening screw for user interface area
(must be screwed to ensure personnel
protection)
DC output terminal :
PHOENIX CONTACT PC 16/4-GF-10,16 BK
for models YPO 12-16, 12-25, 12-40, 24-
12, 24-20 and 24-30.
PHOENIX CONTACT PC35 HC/4-GF-15,00
BK for models YPO 12-60.
Removable front
cover