Intended use / Safety advice
Rapid Charger TLG 1000 B3
Intended use
Q
The universal battery charger is intended
exclusively for:
-
Charging rechargeable Ni-Cd and Ni-MH
batteries of types AAA/AA/C/D and 9 V block.
-
Private, non-commercial use.

Included items

Q
1 Rapid Charger TLG 1000 B3
1 Operating instructions

Description

Q
Charging bays for type AAA/AA/C/D
A
batteries (charging bays 1 to 4)
LCD display
B
Charging bays for type 9 V block batteries
C
(charging bays 5 and 6)
LEDs
D

Technical data

Q
Input voltage:
Power consumption:
Protection class:
Charging currents:
Output voltages:
6
GB
66148_tro_Akkuladegeraet_Content_LB4.indd 6
AC 100 – 240 V ~
50/60 Hz
30 W
6 x 500 mA (type AAA)
6 x 1000 mA (type AA)
4 x 1000 mA (type C or D)
2 x 70 mA (9 V block)
6 x 1.2 V
Charging bays 1 - 4
2 x 9 V
Charging bays 5 + 6
Rated capacity:
Rech. battery
Capacity
type (Ni-
(mAh)
MH /
Ni-Cd)
Type AAA
150–1000 0.42-2.8
Type AA
600-2500
Type C
1000-5000
Type D
1000-9000 1.4-12.6
9-V block
100-200

Safety advice

Risk of fire!
Do not position the universal battery
charger:
In places exposed to direct sunlight. Otherwise
this could lead to overheating of and irreparable
damage to the universal battery charger.
In the direct vicinity of sources of heat, such as
boilers, ovens, fan heaters and similar devices,
or the ventilation openings of other electrical
devices. Otherwise this could lead to irreparable
damage to the universal battery charger.
In damp environments or in the vicinity of water.
Otherwise moisture could penetrate the universal
battery charger. There is also the risk of electric
shock or fire.
This device is must be used for charging recharge-
able "Ni-Cd" and "Ni-MH" batteries only. Never
charge other types of rechargeable batteries
or single-use, non-rechargeable batteries. These
types of batteries are not suitable for recharging.
Non-suitable or non-rechargeable batteries
could overheat and explode. This could lead to
irreparable damage to the universal battery
charger and the inserted batteries. Risk of injury!
Charging
Charg-
time ap-
ing cur-
prox. (h)
rent
(mA)
500
0.84-3.5
1000
1.4-7
1000
1000
2-4
70