11. Appendix

11.1 FAQs

QUESTION
Is it possible to connect two
heating circuits to one "Uni-
box T"?
How many m² of surface
heating can be connected to
the "Unibox T"?
Can the "Unibox T" be operat-
ed with an actuator?
102272280-V01.02.2020
RESPONSE
Yes, use a"Duo connection piece" to connect two heating
circuits of the same length to one "Unibox T". Each surface
heating circuit may have a maximum pipe length of 80 m, pro-
vided you use 16/17 mm pipes.
Illust. 11: Connection scheme of two heating circuits with "Duo
connection piece"
You can connect a surface covering approximately 20 m² per
"Unibox T". The pipe length must not exceed 100 m when
using a 17 mm pipe.
Yes, the "Unibox T" can be operated with an actuator. The
actuator is mounted onto the connection for the control piston.
When operating the "Unibox T" with an actuator, you must use
a closed cover.
Appendix
27