J
Equipment works but does not cool
down.
K
The unit does not cool enough.
L
Water filters inside cabin.
M
The unit does not respond to the user's
selection orders.
Symptom
• Compressor do not work.
• Equipment is discharged.
• Blockage in circuits.
• The air distribution interior panel ducts are
not adjusted with the base of the device.
• Excess or lack of gas load.
• Communication cable disconnected or
defective.
• Continuous flow capillary pipe semi-
blocked (may be due to excess oil).
• Recirculation blocked or semi-blocked.
• Condenser/condenser fan grille dirty.
• Condenser fan defective.
• Condenser fan with polarity inverted.
• EPDM joint badly assembled or deteriorated.
• Obstructed drainage pipes or without
drainage valve.
• Electronic control or control panel faulty.