Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be
overridden by depressing the safety stop.
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be draind separately, since non-return valves
are installed in the hot and cold water connections. For
this purpose, the mixer must be removed from the wall.
Adjusting the economy stop
For flow rate adjustment, see figs. [4] to [7]
• The flow rate is limited by a stop, adjusted by the
factory.
If a higher rate is desired, the stop can be overridden by
depressing the economy button (K), see fig. [4].
If the stop is required to be adjusted, proceed as follows:
1. Close shut-off valve.
2. Pull off or unscrew cap (L) and remove screw (M), see
fig. [4].
3. Remove shut-off knob (F), splined adapter (N) and
economy stop (P), see fig. [5].
4. Reinstall economy stop (P) in the desired position. For
adjustment range, see fig. [6].
5. Fit splined adapter (N) and shut-off knob (F) with
economy button (K) facing to the front. Reinstall
screw (M) and refit or screw on cap (L), see fig. [7].
Check function of automatic diverter (R) of bath mixer
34 357, see also fig. [8].
The water supply is turned on by lifting the lever.
The water will always emerge from the bath outlet first of
all. Pulling the changeover selector (R) closes the water
passage to the bath and the water is diverted to the
shower outlet.
When the mixer is turned off, the diverter is automatically
reset to its starting condition, with the result that the water
always flows out of the bath tap when the mixer is turned
on again.
Maintenance
For maintenance, see fold-out page I.
Shut off hot and cold water supplies.
I. Non-return valve.
1. With a 30mm open-ended spanner, unscrew and
remove mixer from unions.
2. Remove dirt strainer (U).
3. With a 12mm hexagon socket spanner, remove union
nipple (T) by turning clockwise (left-hand thread).
4. Remove non-return valve (V).
II. Thermoelement.
1. Pull off or unscrew cap (S).
2. Unscrew and remove (G) and pull off thermostat
knob (E).
3. Unscrew and remove adjusting nut (B).
4. Pull off stop ring (A).
5. With a 24mm open-ended spanner, unscrew and
remove thermoelement (W).
Readjustment is necessary after every maintenance
operation on the thermoelement (see Adjustment).
III. Ceramic headpart.
1. Pull off or unscrew cap (L) and remove
screw (M).
2. Remove shut-off knob (F), splined adapter (N) and
economy stop (P).
3. With a 17mm open-ended spanner, unscrew and
remove ceramic headpart (Y).
IV. Unscrew and clean aerator (13 927), see fold-out
page I.
Reassemble in the reverse order.
Inspect and clean all parts, replace if necessary and
grease with special valve grease (ref. No. 18 012).
Use only genuine Grohe replacement parts.
Replacement parts, see fold-out page I ( * = special
accessories).
Care
For directions on the care of this thermostat mixer, please
refer to the accompanying Care Instructions.