8 - Master messages from Lift Controller to Drive Controller
SBI DRW W0 , bytes are assigned as follows:
12
11
10
9 - Slave messages from Drive Controller to Lift Controller
Messages from the lift controller consist of 6 bytes and comprise:
Command
Data Byte 1
byte
(B10 ... B0)
• Command byte
The first byte of the message is called the command byte. It contains
the following information:
Bit B0
Drive controller enable
0: drive not active
1: drive activated during travel
Bit B1
-
Bit B2
Stop switch
• ----
• ----
Bit B3
-
Bit B4
Direction of travel
0: up
1: down
Bit B5
-
Bit B6
-
Bit B7
-
Bit B8
Multispeed 0
• ----
• ----
Bit B9
Multispeed 1
• ----
• ----
Bit B10 Multispeed 2
• ----
• ----
9
8
7
Response messages from the drive controller consist of 6 bytes and
comprise:
Status byte
Data Byte 1
(S7 ... S0)
Data Byte 2
6
5
4
Data Byte 2
5*
Communi-
Communi-
cat. Byte 1
cat. Byte 2
3
2
5*
Communi-
Communi-
cat. Byte 1
cat. Byte 2
ENGLISH - 5