Herunterladen Diese Seite drucken

gefran SBI-DCP-33 Bedienungsanleitung Seite 12

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2 - Jumper settings on the RV33-4 regulation card
3 – Connection of DCP card (9-pin connector) and DCP master
4 - Motor Autotuning procedure
5 - Menu settings (drive)
 - ENGLISH
S3 (S3-5 and S3-6) __ ON
other jumpers _______ defaul
DATA+ (A) __________ pin 8
DATA- (B) __________ pin 6
REF (GROUND) _____ pin 9
Shield _____________ ground connector
- Close the contactor between the drive and motor.
- +24V must be present on terminal 1
Run the procedure using the keypad on the drive:
SETUP MODE / Autotune / Complete still or Complete rot, see
section 7 of the drive manual.
The Autotuning procedure (4) must have been executed before this
procedure can start.
Switch the drive on and select the FOC (Field Oriented Control) mode
for drives connected to asynchronous motors.
STARTUP / Regulation mode / [1] Field oriented
From STARTUP / Import recipe, select User 1, which contains all the
necessary parameters for DCP communication.
IPA
Description
7106
Seq start sel
7117
Start alt src B2
7072
Mlt spd s 0 src
7073
Mlt spd s 1 src
7074
Mlt spd s 2 src
7037
Ramp ref inv src
9340
Word1 B0 src
9341
Word1 B1 src
9342
Word1 B2 src
9343
Word1 B3 src
9344
Word1 B4 src
9345
Word1 B5 src
9346
Word1 B6 src
9361
W1 decomp src
8999
SBI enable
9010
Drv SBI W0 src
9011
Drv SBI W1 src
6049
Cmp 1 inp 0 src
6044
Cmp 1 function
6046
Cmp 1 delay
6064
Cmp 2 inp 0 src
6065
Cmp 2 inp 1 src
"User 1" recipe
Value
Alternative inp
W1 decomp
B8 W1 decomp
B9 W1 decomp
B10 W1 decomp
B4 W1 decomp
Compare 2 output
RUN cont mon
Drv OL warning
ALM Sequencer
Spd is zero
NULL
BRAKE cont mon
SBI Drv W0 mon
Enabled
W1 comp out
Fault Pin
RUN cont mon
I0 == I1
2.000000
RUN cont mon
Compare 1 output

Werbung

loading

Verwandte Produkte für gefran SBI-DCP-33