AXIS Q3505-SVE Mk II Network Camera
Set focus and zoom limits
These instructions are valid if you have selected Optical zoom for monitoring during camera
startup.
To set focus and zoom for a new preset position:
1. Go to PTZ > Preset Positions and set the focus and zoom for your preferred area in
the camera image.
2. Enter a name for your preset position in the Current position field and select Use
current position as Home.
3. Click Add to add your current position as a preset position.
4. Select your preset position in the Available positions drop-down list.
5. Click Go to to set the camera in your preset position.
6. Click Save.
To set limits for focus and zoom:
1. Go to Video & Audio > Focus & Zoom.
2. Select a value in the drop-down list for Zoom limit to limit the camera's maximum
zoom area.
The digital zoom level is indicated with the letter D.
3. To preview the zoom limit, click Go to this position.
4. Select a value in the drop-down list for Focus near limit to prevent the camera from
focusing on objects that are too close.
5. Click Save.
Note
You can still set focus and zoom in Video & Audio > Focus & Zoom, but your settings are
not saved after camera restart.

Reset to Factory Default Settings

Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available from the support pages
on www.axis.com/techsup
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button and reconnect power. See Hardware Overview on
page 12.