Operating Manual | SKS 40-00 | 4-01 | 8-00 | Headend base units
SKM 1-03, SKM 1-04, SKM 1-05, SKM 1-06,
SKM 2-00, KM 2-03, SKM 2-04,
SKP 2-00, SKP 2-06, SKP 2-10
SKQ 2-06
SKT 2-01
Mount the power supply unit according to the enclosed operating instructions of the power supply unit.
Connect the output combiner to the power supply unit.
The channel strips must be installed according to instructions in section 3.1.
Separate wiring
 The following modules must be wired separately: The modules are supplied with power only via the separate
DC connecting cable.
SKQ 40-xx, SKT 40-xx
SKQ 80-xx, SKT 80-xx
Connecting example SKQ 80-0x/40-0x in the SKS 40-00 with SKZ 5-04
The power supply unit SKZ 5-04 has two DC outputs with a maximum current output of 10 A. Two DC connecting
cables supply the part with power.
Connect the short DC connecting cable to the first SKx 40/80 module and the long DC connecting cable to the
second SKx 40/80 module.
Connect the modules to each other using the enclosed DC connecting cable SKZ 40-00.
The DC connecting cable SKZ 40-01 is used to supply the output combiner. Connect the output combiner to the
last module.
Please pay attention to the maximum number of modules which can be supplied by the power supply
unit (see 5.1 on page 12).
10
2015-12-02 | © AXING AG Switzerland | Subject to change in design and type; errors and misprints reserved
SKZ 5-01
z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01
Connecting example SKT 2-01 in the SKS 40-00 with SKZ 5-01
SKZ 5-04
SKQ 80-0x
SKQ 40-0x
SKQ 80-0x
SKQ 40-0x