3.2.

Power supply in the SKS 8-00 and SKS 4-01

Please pay attention to the maximum number of module which can be supplied by the power supply
unit (see 5.1 on page 12). If required, replace the power supply units with a power supply unit with
greater output current.
Via output combiner
The scope of delivery of the base units SKS 8-00 and SKS 4-01 includes a power supply unit. The output combiner
is mounted ex factory and is already wired.
The following modules are supplied directly via the output combiner:
SKM 1-03, SKM 1-04, SKM 1-05, SKM 1-06,
SKM 2-00, SKM 2-03, SKM 2-04,
SKP 2-00, SKP 2-06, SKP 2-10
SKQ 2-06
SKT 2-01
The channel strips must be installed according to instructions in section 3.1.
SKZ 6-00
z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01
8
2015-12-02 | © AXING AG Switzerland | Subject to change in design and type; errors and misprints reserved
Connecting example SKT 2-01 in the SKS 8-00
SKZ 5-01
z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01 z.B. SKT 2-01
Connecting example SKT 2-01 in the SKS 4-01