SHE chain drive CDs
7

Electrical connection

7.1

Connection example for 2 x CDs

M
24V
=
Blind connector
A
1 2 3 4 5 6
7.2

Connection example for 2 x CDs and 1 x locking drive RM EasyDrive/2

7.3
Unlock the connector
To remove the connector, use a thin screwdriver to carefully push down the locking latch of the connector through the
unlocking hole. Then push out the connector by tilting the screwdriver.
Screwdriver
32
=
Connection cable with plug ca. 1.5 m
L1
N
PE
Colour assignment and function of the power- and connection cable
1 2 3 4 5 6
No.
1
+ -
2
-
+
3
4
5
6
CDs Master drive
Connection cable with plug ca. 1.5 m
CDs Slave drive
RM EasyDrive/2
Unlocking hole
CDs Master drive
CDs Slave drive
Function
Wire profil
24 V 0 V
0.75 mm²
0 V 24 V
0.75 mm²
Bus A
0.25 mm²
Bus B
0.25 mm²
Signal contact
0.25 mm²
Signal contact
0.25 mm²
Connection to the locking drive RM EasyDrive/2
Nr.
Function
1
24 V 0 V
2
0 V 24 V
3
Bus A
4
Bus B
A
Power cable with
connector and
ferrules
B
Wire colour
white
brown
pink
green
yellow
grey
grey
pink
white
Power cable with
connector and
ferrules
Wire profil
Wire colour
0.75 mm²
white
0.75 mm²
brown
0.25 mm²
green
0.25 mm²
yellow
Locking latch
Connector
04/13424999257