GU OPERATION MANUAL FOR NEPTUN
GU OPERATION MANUAL FOR NEPTUN
!!ATTENTION:
Please read these instructions before operating
the lock or set a new combination. We decline any responsibility for
malfunctions due to improper switching or use of force or inappropriate
treatment, or for property or material damage which may be due, for
example, to incorrect safe locking.
Your safe model „Neptun" can be opened with
a master code or a guest code or one of the two
emergency keys provided. Each keystroke is
confirmed by an acoustic signal. Each keystroke
can be corrected by pressing „CANCEL". If you
want that code entered (master or user code) not
be displayed, before entering the code, press
„CANCEL" . Instead of the pressed number, the
screen displays „ -". Non-alkaline battery use is
not recommended.
1. COMMISSIONING:
a. Remove the round cover of the emergency locking system on the
right side of the keyboard.
b. Enter one of the two emergency keys supplied with the notch in
the lock.
c. Turn the key clockwise.
d. Open the door.
e. Turn the key back to the starting position and remove it.
f. Remove the safety screw of the battery compartment cover on the
inner door side.
g. Slide the battery cover to the right.
h. Introduce four 1.5 volt batteries (pay attention to the correct polarity)
AA (alkaline).
i. The display shows „HELLO" - the safe is now operational.
j. Close the battery compartment.
INCORRECT ENTRY
When entering an incorrect code and after pressing „ENTER" key, a fi ve
times beep is heard and the display shows „ERROR 1"; for another in-
correct input the screen displays „ERROR 2" and after three incorrect
entries appear the message „ERROR 3".
LOCKOUT PERIOD AFTER INCORRECT ENTRY
If the code is entered incorrectly three times, a fi ve minutes lockout
period commences. During this fi ve minutes lockout period, a new
entry is not possible.If during lockout period, the electronic lock is
activated and a key is pressed, the display shows „HOLd05" and the
remaining time is counted until expiration. This lockout period cannot be
stopped, not even by removing batteries.
2. BATTERY CHANGE
or opening is not possible, so that batteries should be immediately
changed).
a. If necessary, open the safe using the emergency key (see point 9 - Open
the emergency key).
b. Remove the safety screw of the battery compartment cover on the inner
door side.
c. Slide the battery cover to the right.
d. Remove old batteries.
e. Install new batteries (alkaline) - Note the correct polarity.
f. Close the battery compartment by pushing the battery cover to the right
and tighten it.
Neptun.indd 5
(Display is poor or cannot be read
ATTENTION:
after battery change, the stored codes (master code,
user code) are maintained.
3. MASTER CODE CHANGE
you, is maintained after a battery change)
a. Press „CANCEL" twice.
b. The display shows „SUPER".
c. Enter the current master code (default 0-0-0-0-0-0).
d. Press „ENTER" to confi rm.
e. The display shows „CC --".
f. Enter „0 1" to change the master codes.
g. Press „ENTER" to confi rm.
h. The display shows „NEW".
i. Enter the desired master code (6 digits).
j. Press „ENTER" to confi rm.
k. The display shows the message „REPEAT".
l. Repeat the desired master code (6 digits).
m. Press „ENTER" to confi rm.
n. If the display shows „GOOD", the master code has been changed
successfully.
o. The display shows „CC --"
p. To exit the menu, press „CANCEL".
ATTENTION:
if during programming appears the message
„ERROR", start the procedure from point 5.f.
4. CLOSING - SAVING THE USER CODE
a. Close the door and enter your desired user (four, fi ve or six digits).
b. The display shows the code entered.
c. Press „ENTER" to confi rm the entry.
d. The safe gets automatically locked and the display shows the
message „CLOSE".
e. After proper closing the display shows the message „Closed" and
the selected code.
f. If proper closing is not possible, the display will show „ERROR".
g. Start again closing as described from point 6.
5. OPENING WITH THE USER CODE
a. With the door closed or bolt system pulled out, enter your desired
user code (four, fi ve or six digits).
b. Confi rm by pressing „ENTER".
c. During opening, the display shows „OPEN".
d. After opening the display shows „OPENEd".
INFO
To lock again the safe with the previously selected user code, you must
press only „ENTER", with the door closed.
The safe closes as described at point 6-d and can be opened with the
previously selected user code, as described at point 7.
6. OPENING WITH THE MASTER CODE
a. Press „CANCEL" twice.
b. The display shows „SUPER".
c. Enter the current master code (default 0-0-0-0-0-0).
d. Press „ENTER" to confi rm.
e. The display shows „CC -- „.
f. Enter „0 0" to open with the master code.
g. Press „ENTER" to confi rm.
h. During opening, the display shows „OPEN".
i. Once opened, the display shows the message „OPENEd".
(the master code selected by