When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the device to your trussing system using an appropriate clamp.
For overhead use, always install an appropriate safety bond.
Fehler! Kein gültiger Dateiname.Pull the safety bond through the attachment eyelet and over the trussing
system or a safe fixation spot. Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

Master/Slave-operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the DJ-SCAN 300 you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In),
which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a balanced microphone lead.
Connect the DMX OUT-jack with the DMX IN-plug of the next device.
Set the desired Master-mode - „No DMX Sound" or „No DMX Auto" - for the master-device. Set the DMX
address 1 for all slave-devices.