Herunterladen Inhalt Inhalt Diese Seite drucken

stabo xm 3006e VOX 12/24 Bedienungsanleitung Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The VOX response sensitivity is set with the VOX GAIN regulator on the front of the unit. The
maximum VOX response sensitivity is reached when the regulator is in the right stop position.
The sensitivity setting depends on the volume of your voice, the positioning of the microphone
and the ambient noises.
In order for VOX to work you must set squelch correctly or switch on ASC.
VOX display flashes: VOX blocked with RX signal and open squelch or ASC.
VOX and channel display flash: Transmission (TX) not possible with blocked VOX.
VOX is reactivated after approximately one second once squelch or ASC has been closed.
This prevents unintentional transmissions caused by the reception signal.
The activated VOX function can only transmit if squelch or ASC is activated.
MODE (8) Modulation types AM/FM
In program positions 40/40 and 80/40 you can operate in both FM and AM. Your preferred
modulation type of the two depends on your conversation partners and your own
requirements. However, bear in mind that there is compulsory registration for AM operation in
many countries!
In general, frequency-modulated signals (FM) are less sensitive to interferences from ignition
sparks etc. than amplitude modulated signals (AM). If you hear an unintelligible, distorted
sounding signal in the speaker, it is advisable to try to receive using another modulation type.
To change the modulation type, press the MODE key 8 once. The modulation type is shown
on the display screen as AM or FM. Switch between AM, FM and FM UK in frequency band U.
ANL (Automatic Noise Limiter) (8)
The device is equipped with an automatic noise limiter.
Press and hold the ANL key 8 to switch the ANL on/off. ANL is shown on the display screen
when it is activated.
Note: The ANL only works in AM mode.
EMG (6)
To change the EMG configuration, press the EMG key once, then the EMG is shown in the
display.
Then press and hold the EMG key, EMG flashes and F is also displayed.
Now select the desired channel with the channel switch or the UP/DN keys and select the
desired modulation type by pressing the MODE key.
Press the PTT button once to save the setting. The acoustic signal confirms this.
To change the second EMG configuration, proceed in exactly the same way.
USB CHARGING SOCKET (9)
The USB charging socket 9 can be used to charge smartphones, tablets or other rechargeable
devices with 5 V - 2.1 A.
SCAN (12)
Press and hold the UP or DN button 12 for ± 7 seconds or until a beep sounds to activate the
SCAN function. The dot between the two channel digits flashes to indicate that the function is
active.
The scan stops as soon as a channel is occupied. The scan starts automatically 3 seconds
after the end of the transmission and if a button is not pressed for 3 seconds. In SCAN mode,
turn channel switch 4 or press the UP/DN keys 12 on the microphone to change the scan
direction.
22

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xm cm3008e vox 12/24

Inhaltsverzeichnis