Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (open water
heaters) is not possible.

Safety notes

• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for
indoor use.
• In the case of damage to the external connection cable of the
power supply unit, it must be replaced by the manufacturer
or the manufacturer's customer service department or an
equally qualified person, in order to prevent a hazard.
• The switched-mode power supply connector must not be
directly or indirectly sprayed with water for cleaning purposes.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.

Technical data

• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy economy):
Fitting with switched-mode power supply (36 015, 36 016):
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
Fitting with battery (36 207, 36 208, 36 232, 36 236):
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
• Water connection
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system, see the programme table on page 6.
Special accessories
Further settings and special functions are available via the
infrared remote control (prod. no. 36 206).
Approval and conformity
This product conforms to the requirements of the
relevant EU directives.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
0.05 MPa
Installation
0.1 - 0.5 MPa
max. 1 MPa
Flush pipes thoroughly before and after installation
1.6 MPa
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I and fold
out page II, Fig. [1].
Fasten fitting to wash basin, see Figs. [2] and [3].
approx. 6 l/min
max. 70 °C
Prod. no. 36 236:
60 °C
Lift rod must be inserted into the mixer body during installation,
see Fig. [2].
Connection, see Fig. [4] and [5]
2.4 W
Connecting the voltage supply, see Fig. [6]
Open hot and cold water supply and check that
connections are watertight.
60 s
Setting temperature limiter
1 s
Prod. No. 36 015, 36 207 and 36 236:
1. Remove screw, see Fig. [7].
12cm
2. Turn mixer lever until the desired maximum temperature is
IP 59K
reached.
cold - right
3. Detach mixer lever, see Fig. [8].
hot - left
4. Detach stop ring and reattach with notch pointing vertically
upwards.
5. Turn mixer spindle to the stop, see Fig. [9].
A
6. Assemble mixer lever in horizontal position.
2
2500 V
Prod. No. 36 232:
100 °C
1. Remove screw and stop ring, see Fig. [10].
2. Turn mixer spindle until the desired maximum temperature
is reached.
3. Assemble in reverse order.